Home » Product » Flowmeter » Ele flowmeter
The WT4300 electromagnetic flowmeter (EMF) is widely used in the field of industrial process control, such as metallurgy, papermaking, water supply and drainage, petrochemical, food, heating and other industries. EMF can be used to measure the flowrate of liquids which have an electrical conductivity greater than 5 μS/cm (20 μS/cm for demineralized water) .
Technical characteristics:
☑ Exciting current automatic compensation;
☑ Empty pipe detection by capacitance method;
☑ Conductive rubber and earth electrode are optional.
Technical parameters:
Model |
WT4300E Electromagnetic Flowmeter |
WT4300H Electromagnetic Flowmeter |
|
Meter size |
DN10 ~ DN1000 |
||
Accuracy |
0.5% of rate |
||
Flow range |
0.5 m/s ~ 10 m/s |
||
Electrode material |
Stainless steel 0Cr18Ni12Mo2Ti, Hastelloy B2/C4, Platinum-Iridium, Tantalum, Titanium, etc. |
||
Liner |
Hard rubber, Neoprene rubber, Polyurethane rubber, PTFE, F46, PFA, etc. |
||
Housing |
Aluminum housing(DN10 ~ DN100),Carbon steel housing(DN125 ~ DN1000),Stainless steel housing (option) |
||
Flange |
Carbon steel flange sprayed with zinc and paint for antisepsis, Stainless steel flange (option). |
||
Electrode structure |
Standard electrode, scraper electrode and removable electrode(option) |
||
Protection class |
IP67、IP68 (remote type) |
||
Fluid temperature |
-25℃ ~ +130℃、+150℃/1h(steam cleaning)、-40℃ ~ +180℃ (option) |
||
Ambient temperature |
-20℃ ~ +60℃ |
||
Power supply |
100 ~ 230VAC.、16.8 ~ 26.4VAC.、16.8 ~ 31.2VDC. |
220VAC.±10%、24VDC.±10% |
|
Current output |
Active and isolated 4~20mA |
Active and isolated 4~20mA |
|
Pulse output |
Active 24VDC pulse, passive optocoupler |
Passive optocoupler |
|
Operation mode |
Keys and magnetic bars |
Infrared control |
|
Display |
Narrow screen, English menu |
Widescreen, support menu in Chinese and English |
|
Communication |
HART、RS485(ASⅡ、Modbus)、DP、PA、FF |
RS485(Modbus)、HART(可选) RS485(Modbus)、HART(option) |
|
Test and error checking |
Self-diagnosis, fault record, output current test, control input (output), simulation mode, empty pipe setting, etc. |
Self-diagnosis, fault record, output current test, simulation mode, empty pipe setting, etc. |
|
Others |
Parameter protection, sensor parameters display, range adjustment, zero, small signal cutting, filter, external memory access, number record, etc. |
Parameter protection, sensor parameters display, range adjustment, zero, small signal cutting, filter, number record, etc. |
WeChat scanwelltech